Fixes were made to address the following CVEs:
|
|
PAN-317215
|
( VM-Series firewalls on ESXi with Intel E810 NICs using PCI
passthrough) Fixed an issue where the
brdagent
process became unresponsive during data port initialization, which
resulted in system instability, interface outages, HA split-brain
conditions, and unexpected reboots during failover.
|
|
PAN-315919
|
Fixed an issue where GlobalProtect pre-logon tunnel session was not
cleared even after the user was logged in. With this fix, the session
is cleared after the session timeout expires.
|
|
PAN-313849
|
Fixed an issue on Panorama where the
logd
process exited unexpectedly when handling syslog forwarding.
|
|
PAN-311192
|
Fixed an issue where the
device-telemetry collect-now
process became unresponsive when the process was initiated multiple
times with other processes running concurrently, which prevented
subsequent telemetry collection.
|
|
PAN-308377
|
( PA-7050 firewalls in HA configurations only)
Fixed an issue where the firewall reached 100% disk utilization due to
the
logrcvr
process repeatedly restarting and dumping core files due to a blocked
hints processing thread, which caused a failover.
|
|
PAN-306356
|
Fixed an issue where the
logrcvr
process on a firewall stopped responding due to a document node being
unexpectedly freed.
|
|
PAN-303663
|
Fixed an issue on the firewall where SolarWinds monitoring systems
reported 100% usage for Slot1 Data Processor-0 Hardware Packet Buffers
due to an inaccurate reported packet buffer.
|
|
PAN-295806
|
Fixed an issue where memory leaks on the
configd
process occurred due to a hash insert operation failing during
connection management and SSL connections.
|
|
PAN-288175
|
Addressed a stack buffer overflow memory leak under plugin management
code path.
|