This commit is contained in:
@@ -0,0 +1,38 @@
|
||||
<table class="table colsep rowsep table-striped">
|
||||
<!--cq:include script="../../common/tablestack.jsp" /-->
|
||||
|
||||
<colgroup>
|
||||
<col style="width: 25%" />
|
||||
<col style="width: 75%" />
|
||||
</colgroup>
|
||||
<thead class="thead">
|
||||
<tr class="row rowsep">
|
||||
<th class="entry">
|
||||
<div class="p"><b class="ph b">Issue ID</b></div>
|
||||
</th>
|
||||
<th class="entry">
|
||||
<div class="p"><b class="ph b">Description</b></div>
|
||||
</th>
|
||||
</tr>
|
||||
</thead>
|
||||
|
||||
<tbody class="tbody">
|
||||
<tr class="row">
|
||||
<td class="entry">
|
||||
<div class="p"><b class="ph b">PAN-242777</b></div>
|
||||
</td>
|
||||
<td class="entry relcol">
|
||||
<div class="p">
|
||||
Fixed an issue where running debug online diagnostics run on a 5G
|
||||
supported PA-400 firewall models reported "Missing device on I2C bus"
|
||||
errors and did not execute cellular modem diagnostic tests. This
|
||||
occurred because the diagnostics script used an incorrect I2C device
|
||||
list for the 5G supported PA-400 hardware variants and did not
|
||||
recognize it as a cellular-capable platform. With this fix, the I2C
|
||||
scan correctly reflects the 5G supported PA-400 hardware configuration
|
||||
and cellular modem tests run as expected.
|
||||
</div>
|
||||
</td>
|
||||
</tr>
|
||||
</tbody>
|
||||
</table>
|
||||
Reference in New Issue