@@ -0,0 +1,368 @@
<table class="table colsep rowsep table-striped">
<!--cq:include script="../../common/tablestack.jsp" /-->
<colgroup>
<col style="width: 25%" />
<col style="width: 75%" />
</colgroup>
<thead class="thead">
<tr class="row">
<th class="entry">
<div class="p">Issue ID</div>
</th>
<th class="entry">
<div class="p">Description</div>
</th>
</tr>
</thead>
<tbody class="tbody">
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-25370</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where GlobalProtect clients (versions
6.3.3-h2-6.3.3-h4) intermittently failed to honor enforcer bypass
rules for FQDNs and IP addresses after the client machine woke up from
sleep. This resulted in connections to bypassed URLs being blocked,
including GlobalProtect's own SAML authentication requests, and
required a manual restart of the PanGPS service to restore
connectivity.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-25172</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where, on macOS GlobalProtect clients, exclude routes
were not properly removed from the system routing table after a PanGPS
(GlobalProtect client) crash. This occurred because the routes
remained in the macOS kernel, and upon reconnection, the client's
`checkExistingExRts()` function only validated the destination and
netmask, not the gateway. As a result, these stale routes, pointing to
an old or unreachable gateway, were marked as existing and skipped
during the reconnection process, leading to a corrupted routing state
and preventing correct route injection, especially after a network
change.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-25063</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where, in the GlobalProtect app on macOS, keyboard
focus did not automatically move to the required "Enter portal
Address" field when a user attempted to add a new portal without
entering an address. This accessibility issue impacted
keyboard-dependent users.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-24961</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where the firewall, when configured to obtain IP
addresses from a DHCP server for GlobalProtect clients, sent a MAC
address of '00' to the DHCP server specifically for MacOS 26 (Tahoe)
clients running GlobalProtect App versions 6.2 or 6.3, which resulted
in IP address collisions on the DHCP server.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-24897</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where the GlobalProtect Connect Before Logon tunnel
disconnected for new users on their first logon. This issue affected
GP client versions 6.2.8-hx and 6.3.3-hx.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-24892</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where the GlobalProtect Portal welcome page, when
displayed in German, incorrectly presented a button labeled 'Genau'
instead of 'Zustimmen' (Accept).
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-24880</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where GlobalProtect clients, after upgrading to
versions 6.2.8-263, 6.3.3-h2, or 6.3.3-h3, would get stuck in a
connecting loop and fail to connect to the portal or gateways. This
occurred because the GlobalProtect app crashed when attempting to
delete previous SAML user data, specifically when the user data folder
path contained non-ANSI characters that the app could not convert to a
UTF-16 path.
</div>
</td>
</tr>
<tr class="row">
<td class="entry">
<div class="p"><b class="ph b">GPC-24842</b></div>
</td>
<td class="entry relcol">
<div class="p">
(macOS only) GlobalProtect crashed when you clicked
<span class="ph uicontrol">Change Portal</span> on setups that
included two or more portal entries and had a preferred gateway
marked.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-24835</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where split tunneling domain exclusions on
GlobalProtect App version 6.3.3-C711 for Windows clients failed to
function as expected after the application disconnected and
reconnected. This resulted in traffic for domains configured for
exclusion being incorrectly routed through the VPN tunnel instead of
directly, because the TTLMap for split tunneling domain rules was not
properly cleared when the GlobalProtect App re-established its
connection.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-24804</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where GlobalProtect clients running version 6.3.3-711
would randomly get stuck in a 'connecting' status, preventing them
from establishing a successful VPN connection.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-24796</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where GlobalProtect HIP reports on macOS devices
intermittently failed with an "Invalid client IP" error. This occurred
on GlobalProtect client version 6.2.8-h4 (c317) due to a race
condition where the HIP report thread sent the report during the VPN
disconnect transition, causing the client to use a stale tunnel IP
address instead of the physical IP address.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-24755</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where the GlobalProtect client on Windows machines
truncated the Proxy Auto-Configuration file URL (autoConfigURL) at 104
characters when configured through the GlobalProtect Portal,
preventing the full URL (up to 256 characters) from being correctly
set in the Windows registry due to an insufficient internal buffer
size.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-24515</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where GlobalProtect clients on macOS devices,
specifically version 6.3.3-h2, were unable to resolve internal IPv6
domains when split tunneling was enabled and the operating system
lacked native IPv6 connectivity. This occurred because the client's
logic, which was designed to apply IPv6 configuration only when the OS
already had native IPv6 connectivity, prevented the GlobalProtect
tunnel from properly handling IPv6 traffic, resulting in "Err name not
resolved" errors for internal FQDNs.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-24242</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where GlobalProtect portal authentication failed for
some macOS users when attempting to use saved credentials. This issue,
observed on GlobalProtect client versions 6.2.8 and 6.3.3, resulted in
an immediate authentication failure on the client and firewall logs
indicating an invalid username or password, even though the
credentials were valid for other macOS clients.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-24216</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where the Host Information Profile (HIP) banner was not
displayed on Windows 11 client machines running GlobalProtect client
versions 6.2.8-h7 and 6.3.3. This occurred due to a timing or race
condition where the GlobalProtect client (PanGPA) received an outdated
status, preventing the visual display of HIP match or not-match
notifications, even though the messages were recorded in the client
logs.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-23963</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where GlobalProtect Client version 6.2.8 running in
Windows 365 environments, would experience PanGPA getting stuck during
the tunnel rename process. This prevented successful gateway
authentication and registration after users closed and re-opened their
Windows 365 session, leading to a pop-up message prompting users to
re-authenticate.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-23787</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where GlobalProtect clients on macOS devices, after
upgrading to version 6.2.8-h2, were unable to connect to the
authentication server. This occurred because incorrect logic in the
GlobalProtect Agent code prevented the Webview Process ID from syncing
with the Network Extension process, causing the Network Extension to
block SAML authentication traffic, resulting in a "Could not connect
to the authentication server" error and a blank embedded browser
during SAML authentication.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-23723</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where GlobalProtect clients running version 6.2.8-h1
(6.2.8-c223) experienced intermittent connection failures and
disconnections, with the client agent getting stuck in a 'connecting'
state even when backend logs indicated a successful connection. This
occurred because, when conditional connect mode was enabled, the
client attempted to impersonate a user and write On-Demand settings to
the user's registry hive (HKEY_CURRENT_USER) during pre-logon. As no
user was logged in at that stage, user impersonation failed, leading
to incorrect registry access or failed registry operations, which
caused service instability or misconfiguration.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-23090</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where the GlobalProtect app experienced connectivity
issues after the host computer resumed from sleep mode due to a
missing self-pointed route. This issue resulted in a delay of 5 to 10
minutes for the GlobalProtect connection to get stabilized.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-21852</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where the GlobalProtect Agent incorrectly displayed
"N/A" in the "Last Scan Time" field for the Trend Micro Deep Security
Agent within the Host Information Profile (HIP) report.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-20621</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where users from overseas locations were disconnected
from GlobalProtect due to the HIP report not being sent with manual
gateway selection.
</div>
</td>
</tr>
<tr class="row rowsep">
<td class="entry">
<div class="p"><b class="ph b">GPC-18976</b></div>
</td>
<td class="entry relcol">
<div class="p">
Fixed an issue where GlobalProtect client 6.1.1-5 would select the
incorrect Windows tile by default after locking the screen when using
Single Sign-On for Smart Card PIN (Windows) with the Yubikey Smart
Card Minidriver. When multiple smart cards were present, GlobalProtect
incorrectly selected the last enumerated card instead of the currently
active one.
</div>
</td>
</tr>
</tbody>
</table>