Add data for 10.2 issues, addressed and known
This commit is contained in:
@@ -0,0 +1,31 @@
|
||||
---
|
||||
type: Addressed
|
||||
product: PAN-OS
|
||||
version: 10.2.0
|
||||
source: common-crawl
|
||||
crawl: CC-MAIN-2026-12
|
||||
---
|
||||
|
||||
## PAN-231823
|
||||
|
||||
A fix was made to address [CVE-2024-5916](https://security.paloaltonetworks.com/CVE-2024-5916).
|
||||
|
||||
## PAN-186143
|
||||
|
||||
Fixed an issue where no local changes could be made on a ZTP-enabled device after an upgrade to PAN-OS 10.1.x.
|
||||
|
||||
## PAN-182634
|
||||
|
||||
```caveat
|
||||
PA-400 series firewalls only
|
||||
```
|
||||
|
||||
Fixed an issue where the firewall detected a Power Supply Unit (PSU) failure for the opposite side when disconnecting a PSU from the device. This issue occurred when redundant PSUs were connected.
|
||||
|
||||
## PAN-178165
|
||||
|
||||
Fixed an issue where the CLI command set system setting ctd ctd-agent-assigned-cores 0 to change assigned cores for the ctd-agent failed.
|
||||
|
||||
## PAN-175950
|
||||
|
||||
Fixed an issue where IoT Security (without Strata Logging Service) onboarding failed.
|
||||