## PAN-290996
Fixed an issue where SNMP walks returned a value of 0 for the CPS (Connections Per Second) per vsys on firewalls after upgrading to PAN-OS 11.1.6-h3, even when active connections were present.
## PAN-290803
```caveat
VM-Series firewalls on Microsoft Azure environments only
```
Fixed an issue where firewall failed to bootstrap with a custom image, and VM-Series plugin information was not displayed in the system information.
## PAN-290088
Fixed an issue where a memory leak occurred related to the configd process when pushing configurations from Panorama to a firewall. This occurred when the configurations contained shared policy rules.
## PAN-289763
```caveat
PA-5400f firewalls only
```
Fixed an issue where SD-WAN SaaS monitoring did not work with URL monitoring.
## PAN-288929
Fixed an issue where the preferred_wnd value provided by CTD (Content Threat Detection) was disregarded due to TCP bandwidth estimation, which prevented the window from closing.
## PAN-288363
Fixed an issue where the MIB ID returned an incorrect value via SNMP.
## PAN-287818
Fixed an issue where sessions timed out sooner than expected due to the pan_proxy_accumulation _restore_timeout not initiating when the accumulation session_init failed.
## PAN-287601
Fixed an issue on Panorama where commits took longer than expected.
## PAN-287056
Fixed an issue where BGP export policy rules with next-hop matching failed to block the advertisement of static routes, and the firewall incorrectly matched the egress interface IP address instead of the original next-hop IP address of the static route, which caused the deny rule to fail.
## PAN-287035
Fixed an issue where, when an application stopped responding, a large file was created in the /opt/panlogs directory, which caused the partition to fill up.
## PAN-287023
Fixed an issue where a large number of logs caused the logrcvr process to stop responding.
## PAN-287002
A fix was made to address [CVE-2025-0133](https://security.paloaltonetworks.com/CVE-2025-0133).
## PAN-286306
Fixed an issue where, when getting transceiver information from ESCC for SFP 25G modules, the transceiver code was incorrectly updated with Unknown instead of 25GBase-SR.
## PAN-284744
A fix was made to address [CVE-2025-4229](https://security.paloaltonetworks.com/CVE-2025-4229).
## PAN-278288
Fixed an issue where IPv6 BGP peering established between virtual routers even without dataplane connectivity. This occurred because the firewall used the kernel for lookups instead of the dataplane.
## PAN-268787
Fixed an issue where users were unable to log in to Panorama and the following error message was displayed: Timed out while getting config lock. Please try again. This occurred when pushing configurations to a large number of devices.