Files
firewallissues/web/data/issues/PAN-OS/addressed/11.2.7-h18.md
T

1.8 KiB

type, product, version
type product version
Addressed PAN-OS 11.2.7-h18

BLANK-000000

Fixes were made to address the following CVEs:

PAN-308775

Firewalls in active/passive configurations only

Fixed an issue where NTP status intermittently showed as rejected on the active firewall, which prevented the firewalls from synchronizing time.

PAN-308606

Fixed an issue where traffic was blocked due to a mismatch between the URL category specified in the Security policy rule and the URL filter profile when custom URL categories with the same FQDN were configured.

PAN-295854

Fixed an issue where the firewall generated two URL logs for a single session.

PAN-293707

Fixed an issue where the iotd process failed to install DPI Cloud server FQDN due to a configuration parsing failure, caused by the configuration XML memory buffer not being NULL terminated. This resulted in the accumulation of EAL logs and DLP forwarding being stopped.

PAN-289895

Fixed an issue where, when SSL decryption was enabled, traffic matching a deny rule was incorrectly allowed until the SSL handshake was complete.